MOQ: | 1 |
Preis: | Customized |
Standardverpackung: | Sperrholzkiste |
Lieferfrist: | 30 Tage |
Zahlungs-Methode: | t/t |
Lieferkapazität: | 5 Sätze pro Monat |
IEC 60335-2-11 Clause 20.101 Integrated Door Endurance Testing Machine For Refrigerators Test
Product information:
The integrated door endurance testing machine conforms to IEC60335-2-4:2008 clause 18, IEC60335-2-11:2008 clause 20.101, IEC60335-2-7:2016 clause 18 and 22.104, IEC60335-2-24:2020 clause 23.3 and etc.
Samples and restrictions:
Refrigeration appliances (refrigerators, freezers), ice cream machines and ice makers (single-phase ≦250V, others ≦480V, DC ≦24V), microwave ovens, ovens.
Test purpose:
Used to perform durability life test and tension test when locking the door on the interlocking device of the cover or door of the refrigerator and freezer. To verify the reliability of the interlocking device. It is also used to assist other tests to perform repeated door opening and closing actions. Such as defrosting test and refrigerant leakage test.
Test principle:
The motor drives the mechanical arm to drive the door or cover sucked by the vacuum suction cup to reciprocate at a certain speed. This verifies the reliability of the interlocking device. A force sensor is installed on the mechanical arm to form a closed-loop control with the servo motor. The door opening force value can be accurately controlled and measured.
Equipment structure:
The equipment consists of an electrical control cabinet (including a load voltage regulator), a rack, and a mechanical arm mounted thereon.
The overall frame structure is adopted, and the sample is placed on the bottom plate of the equipment, so that the relative movement is internal stress, reducing the shaking of the equipment. A column-type structure is installed on the bottom plate. The left column contains a set of upper and lower door opening and closing mechanisms. The right column contains a set of left and right door opening and closing mechanisms. At the same time, the bottom plate adopts a centering structure, which is compatible with left and right opening tests (not at the same time).
Equipment dimensions: Approximately: 1800×1300×2200 (mm) W×D×H, Equipment weight: 350kg
Safety protection device: Leakage protection, overload and short circuit protection, overload, short circuit protection
Use environment:
Power supply: AC220V±10%/50-60Hz, power 6KW
Air source: 0.5-0.7MPa compressed air
Use place: atmospheric pressure 80~106kpa; ambient temperature 5~40°C; relative humidity (20~80)%RH; no violent shaking, vibration, no electromagnetic interference, no dust, no explosive and corrosive gases, good heat dissipation
Technical parameter:
Test station | Double stations, including 1 station for upper and lower opening and 1 station for left and right door opening |
Electrical control method | PLC intelligent integrated control, 7-inch human-machine touch interface operation |
Drive method | Servo motor drive |
Sample clamping method | Vacuum suction cup, pneumatic |
Testable sample range |
The following types of samples, WDH = (0.5 ~ 1.2m) × (0.5 ~ 0.7m) × (0.8 ~ 2.0m) and microwave oven, oven |
Test items |
1. Durability test of vertical refrigerator door interlock device (compatible with left and right opening) 2. Durability test of microwave oven and oven switch cover |
Column | There are 2 columns on the platform (left and right columns), each column has a built-in lifting mechanism, which can adjust the height of the robot arm suction cup to match the opening and closing of the door |
Mechanical arm | 2 sets of door opening and closing mechanical arms (one set on each of the left and right mechanical arms), the mechanical arms and the suction cups are rigidly connected |
Adsorption structure | Vacuum suction cup, continuous and stable adsorption, will not fall off, 2 sets |
Opening and closing speed | 0-360°/s (1.5m/s), pre-settable |
Opening and closing angle | 0-130°, pre-settable |
Number of tests | 0-999999 times, pre-settable |
Opening and closing force value | 0-200N, display and judgment results |
Load voltage | 0-250V, adjustable |
Auxiliary action mechanism | Linear action pressing cylinder (optional) |
![]() |
MOQ: | 1 |
Preis: | Customized |
Standardverpackung: | Sperrholzkiste |
Lieferfrist: | 30 Tage |
Zahlungs-Methode: | t/t |
Lieferkapazität: | 5 Sätze pro Monat |
IEC 60335-2-11 Clause 20.101 Integrated Door Endurance Testing Machine For Refrigerators Test
Product information:
The integrated door endurance testing machine conforms to IEC60335-2-4:2008 clause 18, IEC60335-2-11:2008 clause 20.101, IEC60335-2-7:2016 clause 18 and 22.104, IEC60335-2-24:2020 clause 23.3 and etc.
Samples and restrictions:
Refrigeration appliances (refrigerators, freezers), ice cream machines and ice makers (single-phase ≦250V, others ≦480V, DC ≦24V), microwave ovens, ovens.
Test purpose:
Used to perform durability life test and tension test when locking the door on the interlocking device of the cover or door of the refrigerator and freezer. To verify the reliability of the interlocking device. It is also used to assist other tests to perform repeated door opening and closing actions. Such as defrosting test and refrigerant leakage test.
Test principle:
The motor drives the mechanical arm to drive the door or cover sucked by the vacuum suction cup to reciprocate at a certain speed. This verifies the reliability of the interlocking device. A force sensor is installed on the mechanical arm to form a closed-loop control with the servo motor. The door opening force value can be accurately controlled and measured.
Equipment structure:
The equipment consists of an electrical control cabinet (including a load voltage regulator), a rack, and a mechanical arm mounted thereon.
The overall frame structure is adopted, and the sample is placed on the bottom plate of the equipment, so that the relative movement is internal stress, reducing the shaking of the equipment. A column-type structure is installed on the bottom plate. The left column contains a set of upper and lower door opening and closing mechanisms. The right column contains a set of left and right door opening and closing mechanisms. At the same time, the bottom plate adopts a centering structure, which is compatible with left and right opening tests (not at the same time).
Equipment dimensions: Approximately: 1800×1300×2200 (mm) W×D×H, Equipment weight: 350kg
Safety protection device: Leakage protection, overload and short circuit protection, overload, short circuit protection
Use environment:
Power supply: AC220V±10%/50-60Hz, power 6KW
Air source: 0.5-0.7MPa compressed air
Use place: atmospheric pressure 80~106kpa; ambient temperature 5~40°C; relative humidity (20~80)%RH; no violent shaking, vibration, no electromagnetic interference, no dust, no explosive and corrosive gases, good heat dissipation
Technical parameter:
Test station | Double stations, including 1 station for upper and lower opening and 1 station for left and right door opening |
Electrical control method | PLC intelligent integrated control, 7-inch human-machine touch interface operation |
Drive method | Servo motor drive |
Sample clamping method | Vacuum suction cup, pneumatic |
Testable sample range |
The following types of samples, WDH = (0.5 ~ 1.2m) × (0.5 ~ 0.7m) × (0.8 ~ 2.0m) and microwave oven, oven |
Test items |
1. Durability test of vertical refrigerator door interlock device (compatible with left and right opening) 2. Durability test of microwave oven and oven switch cover |
Column | There are 2 columns on the platform (left and right columns), each column has a built-in lifting mechanism, which can adjust the height of the robot arm suction cup to match the opening and closing of the door |
Mechanical arm | 2 sets of door opening and closing mechanical arms (one set on each of the left and right mechanical arms), the mechanical arms and the suction cups are rigidly connected |
Adsorption structure | Vacuum suction cup, continuous and stable adsorption, will not fall off, 2 sets |
Opening and closing speed | 0-360°/s (1.5m/s), pre-settable |
Opening and closing angle | 0-130°, pre-settable |
Number of tests | 0-999999 times, pre-settable |
Opening and closing force value | 0-200N, display and judgment results |
Load voltage | 0-250V, adjustable |
Auxiliary action mechanism | Linear action pressing cylinder (optional) |